10
To activate External Control Only mode:
1. Stop the pump by pressing the Start/Stop button.
2. Activate External Control Only mode by pressing and
holding the Start/Stop button for 3 seconds.
3. If successful the LED next to Ext. Control Only will
illuminate. See Figure 7.
4. The Start/Stop button must be pressed again to allow
the pump to run.
9 : 00
Pm
Figure 7: Activating External Control Only

Setting the Clock

When the pump is first plugged in, the clock will blink to
indicate that is has not been set. Any daily schedule set by the
user will be based on this clock setting, so it will be necessary
to set the clock first.
To Set the Clock:
1. Press and hold the Display button for 3 seconds.
2. Use the "+" and "-" arrows to choose between a 12 or 24
hour time format.
3. Press Display to advance in the Clock Setup menu
4. Use the "+" and "-" arrows to change the time to the
correct time of day. In the 12 hour time format AM/PM
will display in the bottom right corner.
5. Press Display to advance.
6. Use the "+" and "-" arrows to adjust the screen backlight
brightness.
7. Press Display to exit the Clock Setup menu. The clock
is now set.
If the drive has lost the user set time, the clock will continuously
blink until the time is reset.
To deactivate External Control Only mode:
1. Stop the pump by pressing the Start/Stop button.
2. Deactivate External Control Only mode by pressing and
holding the Start/Stop button for 3 seconds.
3. If successful the LED next to Ext. Control Only will turn
off. See Figure 7.
4. The Start/Stop button must be pressed again to allow
the pump to run.

OPERATING THE PUMP

Once the time is reset the clock will stop blinking.
Note: When power is returned to the pump after a prolonged
outage the clock will automatically set itself to the Speed 1
start time, blink and advance. The pump will also run the
associated schedule from that start time.
Using the Default Schedule
The default schedule is designed to provide enough daily
turnover to service a typical pool. See Table 2 for default
schedule.
Duration
(Hours)
SPEED 1
2
SPEED 2
10
SPEED 3
2
Table 2: Default Schedule.
Speed
(RPM)
3000
1400
2200

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Superflo vs2Whisperflo vs2

Inhaltsverzeichnis