IMPORTANT INFORMATION
•
Follow the detailed instructions for connecting the refrigerant pipes to the indoor unit and outdoor
unit. We can only provide a warranty if the lines are installed correctly as described in the instructi-
ons.
•
Do not remove the sealing caps and stoppers until immediately before you install the lines.
•
To prevent leaks, ensure that the quickrelease screw connections are absolutely free of dirt. Moisture
or foreign bodies will adversely affect the function of the quickrelease connectors, leading to a risk
of refrigerant loss (not covered by the warranty).
•
Only install refrigerant lines outdoors in dry weather.
•
The refrigerant lines must not be installed and then plastered over.
•
Please make sure that refrigerant is never allowed to enter the environment. Improper handling of
refrigerant may be harmful to health. Always wear work gloves and goggles when handling refrige-
rant.
•
Do not smoke during the installation work. The equipment must never be operated without the
refrigerant lines connected, otherwise the equipment will be damaged immediately.
•
The screw connections may only be tightened using the appropriate open-ended spanner.
Refrigerant pipe
Connectors (both ends):
G
NOTE
To distinguish the connectors to be connected to the indoor unit and outdoor unit, the
connectors of the refrigerant pipe has been labelled "A", "B","C"and "D". Ensure the marks on
the connectors are the same to the indoor's and outdoor's respectively during connection.
•
Remember that if they are tightened with too little torque, they will leak, but if they are tightened
with too much torque, the screw connections may suffer damage. If you should not be confident
about connecting the refrigerant line connectors yourself, it is imperative that you contact your cus-
tomer service team or a refrigeration contractor.
Important! The EQ valves are only designed for one-time installation. Their seal can not be guaranteed if
they are installed on more than one occasion. This will also void the warranty.
CONNECTING THE REFRIGERANT PIPES TO INDOOR UNIT
1.
Do not remove the plastic seals from the indoor equipment and the appropriate refrigerant pipe until
immediately before you connect them.
2.
Align the refrigerant pipes correctly, make sure the dimensions of the connecting refrigerant pipe
are the same. Place the screw connector on the refrigerant pipes just on to the thread on the indoor
equipment and tighten the first few threads by hand.
Q_instal_SC42xx_SC52xx_SCJAxx19 EU ('20) V4.indd 79
4
79
79
04-08-20 10:32