Mounting and Connection Instructions Electromechanical Blocking Element 1
3.
Mounting instructions
3.1
Dimensioned drawing
All dimensions in mm
14,5
4,5
16
Counter unit
with flange
max. 4mm
25
Threaded sleeve with hexagon socket
for mounting in wooden doors
Note:
The counter unit and face plate
are available as accessories in
different sizes.
(See list in Chapter 9).
Borehole for threaded sleeve:
Material
Borehole-
Soft wood, plywood, particle
19.5 to 20.0 mm
boards
Hard wood, MDF boards
20.0 to 20.5 mm
These values are approximate values.
If necessary, establish the optimum borehole diameter by experimenting. The
harder the material, the larger the borehole diameter must be.
32
18,7
20
10
2
18
Magnetic contact (019 033 only)
Details see 3.4
Borehole depth
28 mm
18
Mounting and Connection Instructions Electromechanical Blocking Element 1
17
3.2
Installation guidelines
The blocking element is mounted in the door frame, the counter unit or the threaded
sleeve in the door leaf.
ATTENTION:
In order to be able to remove the locking element at a later date, (e.g. for
exchanging a defect locking bolt), ensure that the cable is long enough.
Lay the cable to the next distributor in an empty pipe.
it.
Incorrect!
Correct
Sperrelement
Do not plaste over