PROBLEM
Grinder running
continuously
Espresso runs out
around the edge of
the portafilter
and / or
Portafilter comes
out of the group
head during an
extraction
Issues with the Auto
Start feature
ERR error message
on LCD
Pumps continue to
operate / Steam is
very wet / Hot water
outlet leaks
26
POSSIBLE CAUSE
• No beans in hopper.
• Tamping fan has been
removed.
• Portafilter not inserted in the
group head correctly.
• There are coffee grounds
around the filter basket rim.
• Filter basket rim is wet or
underside of portafilter lugs
are wet. Wet surfaces reduce
the friction required to hold the
portafilter in place whilst under
pressure during an extraction.
• Clock not set or clock is set
with incorrect time.
• A major fault has occurred
and machine cannot operate.
• Using highly filtered,
demineralised or distilled
water which is affecting how
the machine is designed
to function.
WHAT TO DO
• Fill hopper with beans.
• Rotate the portafilter to the left to
stop the auto grind, dose & tamp
function.
• Check that the tamping fan is in
position and mounted correctly to
the drive shaft, page 20.
• Ensure portafilter is rotated to the
right until the handle is past the
centre and is securely locked in
place. Rotating past the centre
will not damage the
silicone seal.
• Clean excess coffee from the rim
of the filter basket after grinding to
ensure a proper seal in group head.
• Always ensure filter basket and
portafilter are dried thoroughly before
filling with coffee, tamping and
inserting into the group head.
• Check that the clock and Auto
Start time have been programmed
correctly. The LCD will display a
clock icon when the Auto Start time
is programmed.
• Contact Sage
Customer Service
®
Centre or visit
www.sageappliances.com
• We recommend using
cold, filtered water. We do not
recommend using water with
no / low mineral content such
as highly filtered, demineralised
or distilled water. If the problem
persists, contact Sage
Service Centre.