Parameterization and configuration
6.8 TR-Mode High Resolution
Availability
Configuration data
Data Exchange
Byte
X+0
X+1
X+2
X+3
Byte
X+0
X+1
X+2
X+3
Parameter data, [x] = Default, Byte-Order = Big Endian
Byte
Parameter
Count direction
Short diagnostics
1
(16 Byte)
Commissioning
diagnostics
2
Status-byte
3-6
Total measuring range
7-10
Revolutions numerator
11-12
Revolutions denominator
13-16
Lower limit switch
17-20
Upper limit switch
TR-Electronic GmbH 2010, All Rights Reserved
Page 86 of 111
●
COH, TR0DAAAB.GS_
●
0xF1: 1 double word input data for position value, consistent
1 double word output data for preset adjustment value, consistent
Bit
Input double word IDx
31
24
2
–2
Position value
23
16
2
–2
Position value
15
8
2
–2
Position value
7
0
2
–2
Position value
Bit
Output double word ODx
31
2
Preset execution with rising edge, see page 88
30
24
2
–2
Preset adjustment value
23
16
2
–2
Preset adjustment value
15
8
2
–2
Preset adjustment value
7
0
2
–2
Preset adjustment value
Type
Bit
Bit
Bit
Bit
Unsigned32
Unsigned32
Unsigned16
Unsigned32
Unsigned32
TR - ECE - BA - DGB - 0076 - 08
Description
0: increasing values [x]
Bit 0
1: decreasing values
0: Yes
Bit 1
1: No [x]
0: switched off [x]
Bit 2
1: switched on
0: switched off [x]
Bit 1
1: switched on
Total measuring range in steps
Default = 16777216 steps
Number of revolutions as fraction
Default = 4096 (numerator)
Number of revolutions as fraction
Default = 1 (denominator)
Position value for lower limit switch
Default = 0
Position value for upper limit switch
Default = 4096
Page
89
91
89
98
94
95
95
97
97
Printed in the Federal Republic of Germany
11/07/2018