Parameterization
Corresponding measures in case of an error see chapter "Causes of faults and
remedies", page 170.
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
7.4.3.21 Attribute 45, Supported Alarms
Supported Alarms displays the alarms supported by the measuring system.
WORD, read only
Bit
0
1...11
12
13...15
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
7.4.3.22 Attribute 46, Alarm Flag
The Alarm Flag displays if a position or an EEPROM error occurred.
BOOL
Access
Get
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
TR-Electronic GmbH 2013, All Rights Reserved
Page 138 of 175
0x23
0x24
Logical Type
Class #23
= Instance
Description
Position error
Reserved or not supported
EEPROM error
Reserved
0x23
0x24
Logical Type
Class #23
= Instance
Value
Description
0
no error occurred
1
error occurred
0x23
0x24
Logical Type
Class #23
= Instance
TR-ECE-BA-DGB-0102 v10
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
FALSE (0)
-
-
-
-
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
Printed in the Federal Republic of Germany
0x2C
Attr.-ID #44
TRUE (1)
supported
-
supported
-
0x2D
Attr.-ID #45
0x2E
Attr.-ID #46
01/27/2022