7. Trouble Shooting
Having trouble?
Nothing appears in the wireless remote controller display, the display is
faint, or signals are not received by the indoor unit unless the remote
controller is close.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is flashing.
8. Installation, relocation, and inspection
Before installing, relocating, and inspecting the unit, make sure you read all the "Safety Precautions".
Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
Caution:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause an explosion.
• Where there is much machine oil.
• Salty place such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where there is oil splashing or much oily smoke.
Warning:
If the air conditioner operates but does not cool or heat (depending
on model) the room, consult your dealer since there may be a
refrigerant leak. Be sure to ask the service representative whether
there is refrigerant leakage or not when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant
normally does not leak, however, if refrigerant gas leaks indoors,
and comes into contact with the fire of a fan heater, space heater,
stove, etc., harmful substances will be generated.
Electrical work
• Provide an exclusive circuit for power supply of the air conditioner.
• Be sure to observe the breaker capacity.
Warning:
• The customer should not install this unit. If the unit is installed incorrectly, fire, electric shock, injury due to a falling unit, water leakage,
etc. may result.
• Do not connect using branched outlet or an extension cord, and do not attach many loads to one electric outlet.
• A fire or electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.
Caution:
• Apply grounding
Do not connect a grounding wire to a gas pipe, water pipe, lightning rod or ground wire of a telephone.
If a grounding is incorrect, it may cause an electric shock.
• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid place, etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
Inspection and maintenance
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
• It is recommended to apply inspection and maintenance (charged) by a specialist in addition to normal maintenance. Consult your dealer.
Also consider operation sound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
8
Here is the solution. (Unit is operating normally.)
■ The batteries are low.
Replace the batteries and press the Reset button.
■ If nothing appears even after the batteries are replaced, make sure
that the batteries are installed in the correct directions (+, –).
■ The self diagnosis function has operated to protect the air conditioner.
■ Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
Inverter type
fluorescent lamp
To prevent the effect
of a fluorescent lamp,
keep it away as far
apart as possible.
Radio
Well-
ventilated dry
place
To prevent picture
distortion or
noise, keep 1 m
or more apart.
100 mm or more
400 mm or more
TV