INSTALLATION

Specification

14.2 Opening the appliance

f Pull off the temperature selector and the limiting ring.
f Remove the screws from underneath the temperature
selector.
f Open the appliance cover by lowering the bolt screws in-
wards and pivot the cover upwards, then remove it.

14.3 Descaling the appliance

Material losses
!
Never treat the cylinder surface with descaling agents.
f Remove the flanged immersion heater.
f Carefully tap the heating element to remove large limescale
deposits.
f Immerse the heating element up to the flange plate in desca-
ling agent.

14.4 Checking the earth conductor

f Pull off the temperature selector and the limiting ring.
f Check the earth conductor (in Germany, e.g. DGUV3) across a
temperature controller fixing screw and the earth conductor
contact of the power cable.

14.5 Replacing the power cable

The power cable must only be replaced by a qualified contractor
with an original spare part. Alternatively, the H05VV-F3x1.0 cable
may be used.
14.6 Positioning the temperature sensor in its
protective pipe
f When replacing the temperature controller, guide the tem-
perature sensor into its protective pipe.
f Secure the temperature sensor in place below the earthed
plug.
18
| UFP 5 h
200
15. Specification

15.1 Dimensions and connections

252
100
c06
c01
i13
140
c01
Cold water inlet
Male thread
c06
DHW outlet
Male thread
i13
Wall mounting bracket

15.2 Wiring diagram

1/N/PE ~ 220 - 240 V
70
222
UFP 5 h UFP 5 h LABS
G 1/2 A
G 1/2 A
L N
www.stiebel-eltron.com
G 1/2 A
G 1/2 A