Transport and Storage
EN
4
Transport and Storage
EN
DANGER! Explosion due to damaged seal in devices with enclosure hinges!
EN
Non-compliance may result in serious or even fatal injury.
EN
Devices with enclosure hinges must be transported only with a transport lock.
EN
Transport and store the device carefully and in accordance with the safety notes
EN
(see "Safety" section).
EN
EN
5
Product Selection, Project Engineering and Modification
EN
DANGER! Explosion if the entire device is completely painted after manufacture!
EN
Non-compliance may result in serious or even fatal injuries.
EN
Do not paint the device.
Have all repairs performed by the manufacturer.
EN
EN
DANGER! Explosion due to defective sealing of the device!
Non-compliance may result in serious or even fatal injuries.
EN
Do not create any additional drilled holes to apply labels or plates (on the outside).
EN
Equip the enclosure only with suitable equipment (e.g. cable entries,
EN
EN
EN
Observe the operating instructions from the manufacturers of the components and
EN
Seal any unused cable entries with the stopping plugs approved for the type of
EN
EN
Seal all open drilled holes by means of suitable equipment.
EN
EN
When complying with the installation conditions and specifications on the rating plate:
Check whether enough cable entries are provided. Create additional drilled holes if
EN
necessary, see Section 5.1.
EN
Equip terminals and, if necessary, mount built-in components; see Section 5.3.
The primary methods considered for modification are remachining or retrofitting equipment
to the control and distribution boxes. The following options are available for this:
• Additional drilled holes on the flange plate, either by R. STAHL (Section 5.1.1)
or by the customer (Section 5.1.2.1)
• Additional drilled holes in the enclosure either by R. STAHL (Section 5.1.1)
or by the customer (Section 5.1.2.2)
• External add-on components either by R. STAHL or by the customer (Section 5.2)
• Internal built-in components either by R. STAHL or by the customer (Section 5.3)
8
Terminal Boxes
Series 8150/1, Series 8150/2
stopping plugs, or breathers) that is verifiably approved for use in hazardous areas
and meets the requirements of the IP protection rating.
Examples: EC Type Examination Certificate or IECEx Certificate of Conformity.
seals that are to be installed.
protection.