Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24

3.2.5 Load curve

Boost in ON position
With this setting the CPS2 OEM 24V/40A charger produces a 3-state load curve IUoU: Boost, Absorption, Floating.
Boost Phase: starts up automatically when the charger is turned on if the battery is flat. The current is then at maximum
output.
Absorption Phase: begins when the voltage has reached the maximum Boost level. The current level starts falling.
These two phases combined last a maximum of 4 hours. The current depends on how charged the battery is.
Floating Phase: starts after 4 hours. The voltage switches to the Floating value and the rated current continues to drop.
Boost in OFF position
With this setting, the CPS2 OEM 24V/40A charger produces a single-stage UI type load curve. It generates a constant
voltage, supplying the current required by the battery(ies). Recharging time depends on the state of the battery, being
longer than when the boost is in the ON position.
CPS2OEM24V-40ADEB.DOC
U out
charger
Boost
U boost
4 Hrs
0
I out
charger
Boost
I nom
4 Hrs
0
U out
charger
U floating
0
I out
charger
I nom
0
Absorption
Floating
U floating
t
Absorption
Floating
t
t
t
18

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis