'Devices/00002CC001F4/Nad': 149,
'Devices/00002CC001F4/Serial': '0000500',
'Devices/00002CC005EA/CustomName': 'Hub-1',
'Devices/00002CC005EA/DeviceInstance': 0,
'Devices/00002CC005EA/FirmwareVersion': 'v2.60-beta-29',
'Devices/00002CC005EA/Manufacturer': 358,
'Devices/00002CC005EA/ModelName': 'Color Control GX',
'Devices/00002CC005EA/N2kUniqueNumber': 1514,
'Devices/00002CC005EA/Nad': 11,
'Devices/00002CC005EA/Serial': '0001514',
'Devices/00002CC005EB/CustomName': 'SmartBMV',
[and so forth]
Zum Ändern führen Sie einen SetValue-Aufruf für den unten aufgeführten DeviceInstance-Pfad durch. Oder, was vielleicht
einfacher ist, verwenden Sie das dbus-spy-Tool.
Diese Zeilen lesen es, ändern es dann in 1 und lesen es dann wieder:
root@ccgx:~# dbus -y com.victronenergy.vecan.can0 /Devices/00002CC005EB/DeviceInstance GetValue
value = 0
root@ccgx:~# dbus -y com.victronenergy.vecan.can0 /Devices/00002CC005EB/DeviceInstance SetValue %1
retval = 0
root@ccgx:~# dbus -y com.victronenergy.vecan.can0 /Devices/00002CC005EB/DeviceInstance GetValue
value = 1
[note that numbers, like can0, and 00002CC005EB can ofcourse be different on your system].
Neue Methode - Ändern der Dateninstanz:
Dies gilt nur für die Funktion NMEA 2000-Out.
Die für die NMEA 2000-Out-Funktion verwendeten Dateninstanzen werden in den lokalen Einstellungen gespeichert. An dieser
Stelle ein Ausschnitt aus den Zeilen, der mit dem dbus-spy-Tool aufgenommen wurde, das auch das Ändern von Einträgen
erlaubt (die Dateninstanzen sind die Instanzen "Batterie-", "DC Details-" usw.):
Settings/Vecan/can0/Forward/battery/256/BatteryInstance0
Settings/Vecan/can0/Forward/battery/256/BatteryInstance1
Settings/Vecan/can0/Forward/battery/256/Description2
Settings/Vecan/can0/Forward/battery/256/IdentityNumber
Settings/Vecan/can0/Forward/battery/256/Instance
Settings/Vecan/can0/Forward/battery/256/Nad
Settings/Vecan/can0/Forward/battery/256/SwitchInstance1
Settings/Vecan/can0/Forward/battery/256/SystemInstance
Settings/Vecan/can0/Forward/solarcharger/0/DcDataInstance0
Settings/Vecan/can0/Forward/solarcharger/0/DcDataInstance1
Settings/Vecan/can0/Forward/solarcharger/0/Description2
Settings/Vecan/can0/Forward/solarcharger/0/IdentityNumber
Settings/Vecan/can0/Forward/solarcharger/0/Instance
Settings/Vecan/can0/Forward/solarcharger/0/Nad
Settings/Vecan/can0/Forward/solarcharger/0/SystemInsta
Settings/Vecan/can0/Forward/solarcharger/1/DcDataInstance0
Settings/Vecan/can0/Forward/solarcharger/1/DcDataInstance1
Settings/Vecan/can0/Forward/solarcharger/1/Description2
Settings/Vecan/can0/Forward/solarcharger/1/IdentityNumber
Settings/Vecan/can0/Forward/solarcharger/1/Instance
Settings/Vecan/can0/Forward/solarcharger/1/Nad
Settings/Vecan/can0/Forward/solarcharger/1/SystemInstance
Settings/Vecan/can0/Forward/solarcharger/258/DcDataInstance0
Settings/Vecan/can0/Forward/solarcharger/258/DcDataInstance1
Settings/Vecan/can0/Forward/solarcharger/258/Description2
Settings/Vecan/can0/Forward/solarcharger/258/IdentityNumber
Settings/Vecan/can0/Forward/solarcharger/258/Instance
Settings/Vecan/can0/Forward/solarcharger/258/Nad
Settings/Vecan/can0/Forward/solarcharger/258/SystemInstance
Alte Methode:
1.
Listen Sie die Geräte auf:
root@ccgx:~# dbus -y
com.victronenergy.bms.socketcan_can0_di0_uc10
com.victronenergy.charger.socketcan_can0_di1_uc12983
Seite 114
Venus GX Handbuch
0
1
15
1
233
0
0
0
1
25
0
36
0
0
1
24
0
36
0
0
1
23
0
36
0
<- Data instance for main voltage measur
<- Data instance for starter or mid-volt
<- Source address - no need, also not go
<- Data instance for switchbank
<- Battery voltage & current
<- PV voltage & current
Marine MFD-Integration durch NMEA
2000