6.10 Connecting the camera to ABUS CMS
The following information is required to connect the camera to ABUS CMS software:
IP address/domain name
http port (default 80)
rtsp port (default 554)
User name: installer
Password: <Password> (assigned and modified by installer)
6.11 Notes for installation when using object detection
The camera's object detection can detect people and vehicles as objects. Other disturbances are thus
ignored.
For the object detection to perform optimally, certain frame conditions must be observed during installation or
with the camera's field of view.
1.
The installation height of the camera should be selected between 2.5 and 5 metres. The inclination
should not exceed 10 degrees.
2.
The object height in the selected image section must be between 1/16 and 1/2 of the image height. If
objects in the image are shown too large or too small, they may not be detected correctly.
3.
Note that below the camera a certain area is not under surveillance.
4.
The maximum surveillance distance depending on the focal length of the camera is as follows:
Focal length
2.8 mm
5.
Reflective surfaces in the image section can confuse object detection.
6.
Make sure that there are no branches or leaves in close proximity to the camera in the image section.
7.
Dome cameras are less suitable for outdoor surveillance with object detection, as light scatter or light
reflection can occur in the dome. This affects the object detection.
8.
Do not use object detection in areas with a correspondingly high number or frequency of lenses (people,
vehicles). This results in a high number of alarms.
Max. surveillance distance
10 m
79