Herunterladen Inhalt Inhalt Diese Seite drucken

Nickel-Metal-Hydride (Ni-Mh) Charge Programs - GRAUPNER ULTRAMAT 17 Bedienungsanleitung

Mikroprozessorgesteuertes hochleistungs-schnelllade-, entlade-, und formierungsgerät für nicd-/nimh-, lipo-/liio-/limn-/life- und pb-akkus
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NiCd-Delta-Peak (-∆ ∆ ∆ ∆ ∆ Peak) trigger voltage
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
N i C d
d e l t a - p e a k -
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
v o l t
= 1 0 m V / c e l l
+
INC
This process analyses the voltage peak of the charge curve, which indicates with great
accuracy when the maximum charge capacity is reached.When the charge process is started
the battery voltage initially rises continuously, but as the pack approaches full capacity it begins
to heat up. This in turn causes the battery voltage to fall slightly (Delta-V). The charger detects
and assesses the voltage decline.It is possible to adjust the sensitivity, or trigger voltage (in mV
per cell!) of the automatic cut-off circuit for Ni-Cd batteries. A practical range of values has
proved to be 10 ... 30 mV / cell. Higher voltages often lead to overcharging of the battery,
whereas a lower voltage tends to result in premature termination of the charge process. We
recommend that you check the information supplied by your battery manufacturer, then carry
out a series of test charges to establish the optimum value for your battery.
NiMH
MODE
AUTOMATIC-
program
A set of convenient charge programs for recharging Nickel-Metal-Hydride batteries, as
commonly used for modelling purposes. When the charge / discharge program is finished, the
screen displays the name of the charge program alternating with the message „END", together
with the charge time, the last (dis-) charge current, the charged-in (discharged) capacity and
the battery voltage, and continues to do so until you disconnect the battery. This information can
often give you a useful indication about the Ni-MH pack's charge characteristics and capacity, or
warn you if the charger has incorrectly assessed the pack as being „full".
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
N i M H
a u t o m a t i c
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C : 2 . 5 A
l i m i t e d
+
-
DEC
INC
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
N i M H
m a n u a l
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C : 2 . 5 A
+
-
INC
DEC
The automatic charge termination
circuit (battery full detection) works on
the proven Delta Peak principle (also
known as the Delta-V process), which
-
is already in use in millions of chargers.
DEC
12. NIMH-programs
NiMH
NiMH
MODE
MANUAL-
discharge
program
program
Ni-MH automatic program
In this program the charger detects the type of Ni-MH
battery connected to it, and adjusts the charge current
accordingly to avoid overcharging the pack.
The maximum charge current can be set before you
connect the battery to be charged. This is done using the
INC / DEC buttons; the range available is 0.1 A to 10 A, or
no restriction. The charge process is terminated auto-
matically in accordance with the values already set for
„Ni-MH Delta Peak cut-off voltage".
Ni-MH manual program
Select this program when you simply wish to recharge a
battery using the set charge current. You can adjust the
charge current using the INC / DEC buttons, but only
before you connect the pack for charging. The range
available is 0.1 A to 10 A.The charge process is
terminated automatically in accordance with the values
already set for „Ni-MH Delta Peak cut-off voltage".
NiMH
MODE
MODE
balance
program
charging time
NiCd
MODE
∆ ∆ ∆ ∆ ∆
delta-peak
trigger voltage
25

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

6442

Inhaltsverzeichnis