GB
Problem
Problem
Coating
material drips
from the nozzle
Atomisation too
coarse / Spray
jet pulsates
Too much fog of
coating material
(Overspray)
14. Technical Data
Max. viscosity
Power source
Power consumption
Protection Class
Max. flow rate
Sound pressure level*
Sound pressure output*
Oscillation level*
Weight
* Measured in accordance with EN 50580:2014
Information about the oscillation level
The specified oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational strain.
Attention! The vibration emission value can differ from the specified value when the
electric tool is actually in use, depending on how the electric tool is being used. It is
necessary to specify safety measures to protect the operating personnel. These measures
are based on an estimated shutdown during the actual conditions of use (all parts of the
operating cycle are taken into consideration here, for example periods when the electric
tool is switched off, and, when it is switched on but running without any load).
18
Cause
Cause
•
Nozzle worn
•
Viscosity of coating material too
high
•
Material volume too large
•
Nozzle contaminated
•
Air filter heavily soiled
•
Too little pressure build-up in
container
•
Distance to the object too large
•
Material volume too large
Technical Data
100 DIN-s
230 V
, 50 Hz
~
350 W
I
150 ml/min
75 dB (A); Uncertainty K = 4 dB
86 dB (A); Uncertainty K = 4 dB
< 2.5 m/s²; Uncertainty K = 1.5 m/s²
1.2 kg
Remedy
Remedy
•
Change
•
Thin
•
Reduce the material volume
•
Clean
•
Change
•
Tighten container
•
Reduce distance
•
Reduce the material volume
W 125