Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

SPECIFICATION
Resistance in the temperature range -20
+70
C
o
Resistance at 85
C
o
Resistance at 95
C
o
Resistance at 105
C
o
Response time for a 20
C to 100
C temperature
o
o
step to register a trip
Maximum continuous voltage

5.7 CABLE

The XTR 25 has two separate cables providing
connections for forcer power and position sensor. The
standard cables supplied are flexible and intended for
continuous flex or drag chain applications.
SPECIFICATION / ANGABEN
Overall diameter (nominal)/
Durchmesser gesamt (nomina;l)
Outer jacket material/Material
Außenmantel
Number of conductors/Anzahl Leiter
Size of conductors/Leiterquerschnitt
Screened / Unscreened/Geschirmt/
Ungeschirmt
Minimum bending radius-fixed
routing/Kleinster Biegeradius-Feste
Leitungsführung
Operating temperature-fixed
routing/Betriebstemperatur-Feste
Leitungsführung
Operating temperature- flexible routing/
Betriebstemperatur- Flexible Verlegung
Version 12.2018
Value
Units
C to
o
60 to 750
Ohms
<=1650
Ohms
>=3990
Ohms
>=12000
Ohms
3
s
30
Vd.c.
www.dunkermotoren.com
ANGABE
Widerstand im Temperaturbereich von 20
+70
C
o
Widerstand bei 85
C
o
Widerstand bei 95
C
o
Widerstand bei 105
C
o
Auslösezeit nach der ein Temperatursprung von
20˚C auf 100˚C erkannt wird.
Max. Dauer-Versorgungsspannung
5.7 KABELTYP
Die XTR 25 Reihe hat zwei getrennte Verbindungs-
kabel für Leistungsversorgung und den Lagegeber.
Die erhältlichen Standardkabel sind flexibel, und für
Schleppkettenanwendungen geeignet.
POWER/LEISTUNG
SENSOR/GEBER
8.0 mm
PUR
4
verdrilltes Doppelkabel
1.5mm
(16 AWG)
2
Screened/Geschirmt
42 mm
-30
C to/bis +80
C
o
o
-15
C to/bis +80
C
o
o
Wert
C to
o
60 to 750
1650
<3990
<12000
3
30
5.8 mm
PUR
4 x twiseted pair/ 4 x
0.14mm
(26 AWG)
2
Screened/Geschirmt
42 mm
-30
C to/bis +80
C
o
o
-15
C to/bis +80
C
o
o
Einheiten
Ohms
Ohms
Ohms
Ohms
s
Vd.c.
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis