Bedienmenü
Adresse
Name
5278
LE_DISTANCEU-
NIT
5277
LCRS_FIRST-
ECHOSENSITIVI-
TYCTRL
5279
LCRS_ECHO-
LOSTDELAY
5280
LCRS_ADJUSTE-
VENTECHOLOST
5281
LCRS_CHAN-
GINGVELOCITY
5282
LE_CSTLINTYPE 1
5283
LE_CUSTOMU-
NIT
5412
LCRS_EVALUA-
TIONSENSITI-
VITY
5413
LE_LEVCOR-
ROFFS
5415
LE_CT_ACT-
TABLE
5416
LE_OUTPUT-
MODE
5417
LE_CT_EDIT-
MODE
5418
LCRS_EVALUA-
TIONDISTANCE
5420
LCRS_FREE-
FIELDMODE
5421
LCRS_HIGHB-
LOCKDISTANCE
5423
LCRS_MAP_EN
DX
5425
LE_PVUNIT
72
15.1.7

Abschnitt: Messungskonfiguration

Anzahl Register Zugriff
• Service
• Bediener
1
• read/write
• read only
1
• read/write
• read only
1
• read/write
• read only
1
• read/write
• read only
1
• read/write
• read only
• read/write
• read only
1
• read/write
• read only
1
• read/write
• read only
2
• read/write
• read only
1
• read/write
• read only
1
• read/write
• read only
1
• read/write
• read only
2
• read/write
• read only
1
• read/write
• read only
2
• read/write
• read only
2
• read/write
• read only
1
• read/write
• read only
Micropilot FMR20 MODBUS RS485
Bereich
Datentyp
m: 1010
enum16
ft: 1018
low: 0
enum8
medium: 1
high: 2
0 ... 600
uint16
warning: 0
enum8
alarm: 1
>1m/min: 0
enum8
<1m/min: 1
<10cm/min: 2
no Filter/Test:3
not active: 32989
enum16
active: 33171
see Parameter Ein-
enum16
heit nach Lineari-
sierung
low: 0
enum8
medium: 1
high: 2
–25 ... 25
float32
disable: 32852
enum16
enable: 32887
level: 32949
enum16
empty: 33197
edit manual: 32890
enum16
delete table: 32889
0 ... 21,8
float32
off: 33004
enum16
on: 33006
0 ... 20
float32
0 ... 21,8
float32
see Parameter Ein-
enum16
heit nach Lineari-
sierung
SI-Einheit
Beschreibung
-
Distance unit for
LCRS_PRIMLE-
VOUT_VALUE_
0
-
First echo sensi-
tivity
s
Echo lost delay
(time between
alarm and echo
lost)
-
Defines the lost
echo status
-
Defines maxi-
mum change
velocity of an
echo change
-
Is linearization
table is used
-
Customer level
unit
-
Sensitivity of the
echo detection
-
Level correction
-
States, if linear-
ization table is
active
-
States the output
mode
-
Edit mode of the
linearization
table
m
Max distance
which will be
evaluated
-
Switch to free
field parameters
m
Blocking dis-
tance (distance
from sensor
which is not eva-
luated)
m
End-point of
overlay map
(factory map +
custom map)
-
Level unit
Endress+Hauser