8. TROUBLESHOOTING

8.1 What to do if...
Downloaded from
www.Manualslib.com
CAUTION!
Refer to the chapters on safety.
Problem
The pouch is not
The sealing time is not correct.
sealed correctly.
The cover gasket is dirty or worn.
The pouch is not placed correctly
on the sealing bar.
The sealing bar is worn (the
Teflon coating is burnt).
The blade placed under the
Teflon of the sealing bar is
broken.
Final vacuum is
The set vacuum level is not
poor.
correct.
The cover gasket is dirty or worn.
The cover is not closed correctly.
The cover does
No power supply.
not open.
The cover is
Damaged cover.
cracked or
broken.
"Reconditioning cycle"
The
and
in progress.
buttons flash.
manuals search engine
Possible cause
ENGLISH
Solution
Change the sealing time.
Clean or replace the cover gasket
(contact the Technical Assistance
Service for a replacement).
Position the pouch correctly.
Replace the sealing bar (contact
the Technical Assistance Service
for a replacement).
Replace the blade (contact the
Technical Assistance Service for a
replacement).
Change the vacuum level.
Clean or replace the cover gasket
(contact the Technical Assistance
Service for a replacement).
Close the cover correctly.
Make sure that objects or dirt are
not found between the cover and
tank.
Wait until the power supply is
restored.
Replace the cover (contact the
Technical Assistance Service for a
replacement).
Wait for the end of the
"reconditioning cycle" (15
minutes).