66 | HTD 6xx / HTD 8xx | Checking / calibration
3. Check the position of the spirit level in the calib-
ration device. In the event of center position devi-
ation, perform any necessary adjustment with the
three height adjustable feet on the underside of the
device.
4. Switch on the laser at the calibration device and
align the center of the lens and the center (hole) of
the test screen with the laser cross.
|
1 692 106 011
2019-03-26
5. Switch on the beam setter and click on "APPLICA-
TIONS".
6. Click on "FREE TEST" in the "APPLICATIONS" screen.
7. Switch on the calibration device, set the control to
"0" and select low beam.
8. Select low beam testing on the beam setter.
9. The light-dark cutoff must be within the tolerance
range. Note the intensity value.