WARNING DEVICE NVD-111
Commissioning
The following table contains a list of possible configuration settings.
Switches
DIP 1
Reaction time
(reaction time of the fat
level sensor)
DIP 2
Overflow sensor
KVF-O
DIP 3
Fat level sensor KVF-F
or FAU-104
DIP 4
Acoustic alarm
DIP 5
Relay setting
DIP 6
DIP 5
Relay setting
DIP 6
DIP 5
Relay setting
DIP 6
DIP 5
Relay setting
DIP 6
DIP 7
Repeat alarm in
24 hours
DIP 8
Reset key (ALARM
RESET activation)
Description
ON
Operating mode – delay of the sensor reaction
OFF
Service/test mode – instant sensor reaction
ON
connected
OFF
not connected
ON
connected
OFF
not connected
ON
Acoustic alarm on.
OFF
Acoustic alarm off.
ON
Relays 1 and 2 switch irrespective of the alarm states and
with which sensor. If the alarm status disappears, relays 1
ON
and 2 switch again (if "ALARM RESET" is actuated, the relays
switch again).
ON
Relays 1 and 2 switch, irrespective of the alarm states. After
3 minutes, relay 2 switches again (even if an alarm status is
OFF
present). If the alarm status disappears, relay 1 and/or relay 2
switches again (if "ALARM RESET" is actuated, the relays
switch again).
OFF
In the case of active alarm status, relay 1 switches to overflow
sensor KVF-O and relay 2 switches to fat level sensor
ON
KVF-F/FAU-104. If the alarm status disappears, relay 1
and/or relay 2 switch again (if "ALARM RESET" is actuated,
the relays switch again).
OFF
Relays 1 and 2 switch, irrespective of the alarm states. If an
alarm event is no longer present, relay 1 automatically
OFF
switches back and relay 2 remains unchanged until the alarm
is cleared by actuating "ALARM RESET". It shows that an
alarm occurred.
ON
Repeat alarm on. This also applies to the function of relays 1
and 2.
OFF
Repeat alarm off.
ON
"ALARM RESET" button is activated. The acoustic alarm and
the alarm relay can be reset.
OFF
"ALARM RESET" button is deactivated. The acoustic alarm
and the alarm relay cannot be reset.
EN