2.2 USING THE TOOL MANAGER SOFTWARE
2.2.8 CONFIGURING PARAMETERS OF THE TOOL
Note
• After exiting the offset setting window, you can save the updated parameters to parameter
list.
If you are editing a parameter file read from a connected tool, the parameter file is newly
added on parameter list.
If you are editing a parameter file originally on parameter list, the parameter file is
overwritten.
• The history log acquired in offset setting is saved to the [Offset] folder on history list.
By checking [Minimum Output Mode] on the offset setting window, the tool can be operated
in [Minimum Output Mode].
(When you uncheck [Minimum Output Mode], the tool will return to [Offset Mode].)
[Functional overview]
When the target torque is close to the lower limit of the torque control functioning range
of the tool, you can check whether torque control is available. The tool in this mode is
shut off at the minimum number of pulses (the minimum output). In this case, no history
log is recorded.
After the work in this mode, use a torque tester or a torque wrench to check whether the
torque output by the tool is not more than the target torque.
If any over-torque occurs in this mode, the tool might not be available to such work.