Power to lock
Actuator monitored
Latching
Manual release
Short circuit detection
Cross-circuit detection
Series-wiring
Safety functions
Integral system diagnostics, status
Number of actuating directions
Number of fail-safe digital outputs
Sicherheitsbetrachtung
Standards
Sicherheitsbetrachtung - Verriegelungsfunktion
Performance Level, up to
Category
PFH value
PFD value
Safety Integrity Level (SIL), suitable for applications in
Mission time
Mechanische Daten
Mechanical life, minimum
Note (Mechanical life)
Angular misalignment between solenoid interlock and actuator,
maximum
Holding force F
in accordance with EN ISO 14119
Zh
Holding force F
, maximum
max
Latching force, adjustable, position 1
Latching force, adjustable, position 2
Type of the fixing screws
Ja
Ja
Ja
Ja
Ja
Ja
Ja
Ja
Ja
3
2
EN ISO 13849-1
EN IEC 61508
e
4
5,20 x 10⁻¹⁰ /h
4,50 x 10⁻⁵
3
20 Year(s)
1.000.000 Operations
Bei Verwendung als Türanschlag: ≥ 50.000 Schaltspiele (Türmassen
≤ 5 kg und Betätigungsgeschwindigkeit ≤ 0,5 m/s)
2 °
1.150 N
1.500 N
25 N
50 N
2x M6
6-31