LED indicator / Beeper
► Fig.6: 1. LED indicator
LED indicator / Beeper on the tool shows the following functions.
Function
Check of the LED indi-
cator, lamp and beeper
operation
Detection of switch
trigger operation when
installing battery
Auto-stop with fastening
completion
Alarm against insuffi-
cient fastening
Intermission between
the phases
Double-hitting detection
Alarm for low battery
capacity
Auto-stop with low
remaining battery
capacity
Anti-reset of controller
Overload protection
Overheat protection
Failure to detect heat
of motor
Motor or controller failure
detection
Maintenance alarm
Alarm for unavailable
data communication
(with the tool in connec-
tion with PC)
Indication that data commu-
nication is available (with the
tool in connection with PC)
Status of the tool
When the battery car-
Lights up first in green,
tridge is installed, the tool
next red.
checks for its LED indica-
(And then the lamp
tor, lamp and beeper.
comes on.)
When the battery cartridge
Blinks in red and green
is installed with the switch
alternatively.
trigger pulled, the tool stops
to avoid unintentional start.
The tool setting has
Lights up in green for
been achieved and the
approximately one
tool has stopped.
second.
The tool has not completed
Lights up in red.
the tool setting because the
switch trigger has released
before reaching the set val-
ues. Otherwise, the settings
of "Failure Criteria for Phase"
has been achieved.
The tool is in the inter-
Lights up or blinks in
mitting period configured
green (depending on
by the setting of "Shift to
settings)
the next Phase".
When the operator starts
Lights up in red.
to re-fasten an already-fas-
tened screw, the tool
detect it and stops.
The battery power became
Blinks in red slowly.
low and it is time to replace
the battery cartridge.
The battery power is
Lights up in red.
almost used up and the
tool stopped.
The battery voltage dropped
Blinks in red and green
abnormally for some reason,
alternatively.
and the tool stopped.
An abnormally high
Blinks in red and green
current continued to flow
alternatively.
through the controller
and the tool stopped.
The motor or the control-
Blinks in red quickly.
ler heated up abnormally
and the tool stopped.
The detection unit of
Blinks in red quickly.
the motor fails to detect
the heat because the
cord has broken or other
reasons.
Motor or controller failure
Blinks in red and green
has been detected. At this
alternatively.
time, tool does not work.
A maintenance time has
Blinks in yellow.
come according to your pre-
set number of screws driven.
Data cannot be
Blinks in yellow.
exchanged between the
tool and PC in spite of
the connection.
The tool is connected to
Blinks in green.
PC and data communi-
cation is available.
Status of the LED indicator/beeper
LED indicator
A series of very short
beeps
A series of short beeps
A long beep
A long beep
A series of long beeps
A long beep
A series of short beeps
A series of short beeps
A series of short beeps
A series of short beeps
A series of short beeps
8 ENGLISH
Action to be taken
Beeper
Release the switch
trigger.
–
Retighten the screw.
–
Replace the battery with
fully charged one.
Replace the battery with
fully charged one.
Replace the battery with
fully charged one.
Remove the cause of over-
load and restart the tool. If
no improvement is found,
ask your local Makita
Service Center for repair.
Remove the battery car-
tridge immediately and
cool the tool down.
Remove the battery cartridge
and cool the tool down. If the
indicator does not stop, ask
your local Makita Service
Center for repair.
Ask your local Makita
Service Center for repair.
–
Reset the alarm with the
application software.
–
Restart the application
software and re-connect
the USB cable.
–
–
–
–
–
–