ds2=on
15.0
ds3=on
30.0
60.0
Ds4: Inverter frequency
Ds5: Search Mode
Store the settings by moving DIP switch 6 to "on" and back to "off".
5.4.3 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to "off").
DS-1 3 position switch
DS-2 Charge voltage
DS-3 Charge voltage
DS-4 Frequency
DS-5 Search mode
DS-6 Store setting
Example 1: (factory setting)
1
No 3 position
switch connected
2, 3
GEL 14.4 V
4
Frequency: 50 Hz
5
Search mode off
6 Store setting: off→ on→ off
Store the settings by changing switch ds-6 from off to on, and then back to off.
The LEDs "charger" and "alarm" will flash to indicate acceptance of the settings.
6. MAINTENANCE
The Multi does not require specific maintenance. It will suffice to check all connections once a
year. Avoid moisture and oil/soot/vapours and keep the device clean.
18
13.8
13.2
27.6
26.4
55.2
52.8
off = 50 Hz
off = off
off
DS-1
off
DS-2
off
DS-3
off
DS-4
off
DS-5
→
←
DS-6
Example 2
1
2,3
4
5
6 Store setting: off→ on→ off
6
on = 60 Hz
on = on
off
DS-1
on
DS-2
off
DS-3
off
DS-4
off
DS-5
→
←
DS-6
Example 3
No 3 position
1
switch connected
Gel Long 14.1V
2, 3
Li-ion (LiFePO4)
4
Frequency: 50 Hz
5
Search mode off
6 Store setting: off→ on→ off
Tubular plate or
OPzS batteries in
cyclic mode
on
on
on
on
on
→
←
3 position
switch connected
Tubular plate 15V
Frequency: 60 Hz
Search mode on