Scope of delivery

Tank [1] with pump [2], hose [4], and Instructions for Use [5]. (Fig. 1)

Technical data

Type of device
Max. filling amount
Total contents
Max. spraying pressure
Max. operating temperature
Weight when empty
Material of tank
Where device is carried
Technical residual quantity
Table 1
Assembly
1. Push the tube [4] into the fixture [10] and secure it with the cap nut. (Fig. 3)
Checks
Visual inspection: Are tank [1], pump [2] and hose [4] and piston pressure gauge [16] unda-
maged? (Fig. 1)
+
Pay special attention to the connections between the tank – hose and hose – plug-in
coupling and to the condition of the pump thread.
No leaks: Pump up the empty device to 2 bar (29 psi) (Fig. 11).
► The pressure must not decrease more than 0.5 bar (7.25 psi) within 30 minutes.
Function: Pull up the piston pressure gauge [16] (Fig. 5)
► The pressure must dissipate.
Check the device regularly and after a longer period of non-use, e.g. a winter break.
Have damaged parts or parts that do not work properly repaired immediately by our
Have damaged parts or parts that do not work properly repaired immediately
by a Husqvarna service team
customer service department or by service partners authorized by us.
Preparation
Observe the instructions in the section entitled „Safety".
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
1. Pull up the red piston pressure gauge [16] until the tank is depressurized. (Fig. 5)
2. Press the piston rod with handle [13] down and turn it counterclockwise.
► The piston rod with handle is locked. (Fig. 6)
3. Unscrew the pump [2] from the tank. (Fig. 7)
4. Add the liquid to the tank [1]. (Fig. 8)
5. Check the filling level with the scale [35] on the tank. (Fig. 8)
6. Screw the pump [2] into the tank. (Fig. 9)
7. Press the piston rod with handle [13] down and turn it clockwise.
► The piston rod with handle is unlocked. (Fig. 10)
10 l (2.64 gal)
12.5 l (3.3 gal)
3 bar (43.5 psi)
40 °C (104 °F)
2.8 kg (6.16 lb)
polyethylene
on the side
<0.07 l (< 0.02 gal)
8
ENGLISH
WT 10MP

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis