7 Cleaning
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Let the product cool down to ambient temperature.
3. Clean the product with a dry, fibre-free cloth.
8 Disposal
This symbol must appear on any electrical and electronic equipment placed on
the EU market. This symbol indicates that this device should not be disposed of
as unsorted municipal waste at the end of its service life.
Owners of WEEE shall dispose of it separately from unsorted municipal waste.
Spent batteries and accumulators, which are not enclosed by the WEEE, as well
as lamps that can be removed from the WEEE in a non-destructive manner, must
be removed by end users from the WEEE in a non-destructive manner before it is
handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-
back of waste. Conrad provides the following return options free of charge (more details on
our website):
■
in our Conrad offices
■
at the Conrad collection points
■
at the collection points of public waste management authorities or the collection points
set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply
in countries outside of Germany.
9 Technical data
9.1 Data according to EU regulation 2019/1782
Manufacturer
Commercial registration number
Model identifier
Input voltage
Input AC frequency
Output voltage
Output current
Output power
Average active efficiency
Efficiency at low load (10 %)
No-load power consumption
9.2 Others
Total power..................................... max. 112 W (USB-A port and USB-C™ cable)
Protection class ............................. Class II
Operating temperature .................. 0 to +35 °C
Operating humidity ........................ 10 - 90 % RH
Storage humidity ............................ 5 - 95 % RH
Storage temperature ...................... -10 to +55 °C
Dimensions (L x W x H) (approx.) . 150 x 67 x 26 mm
Weight (approx.) ............................ 403 g (without mains cable)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2484526_V1_0322_jh_mh_en 469609483 I2/O1 en
4
Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau
HRB 3896
USBC-110
100 – 240 V/AC
50 - 60 Hz
USB-C™ cable:
5.0 V/DC, max. 3.0 A, max. 15.0 W
9.0 V/DC, max. 3.0 A, max. 27.0 W
12.0 V/DC, max. 3.0 A, max. 36.0 W
15.0 V/DC, max. 3.0 A, max. 45.0 W
20.0 V/DC, max. 5.0 A, max. 100.0 W
USB-A port:
5.0 V/DC, max. 2.4 A, max. 12.0 W
85.95 %
89.76 %
0.14 W