Herunterladen Inhalt Inhalt Diese Seite drucken

Vaillant aroSTOR VWL B 270/5 Installations- Und Wartungsanleitung Seite 80

Vorschau ausblenden Andere Handbücher für aroSTOR VWL B 270/5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
Fault code
Description
OVER PRESS.
Overpressure inside the
heat pump
FREQ.DEFRO.
Excessive de-icing
LOW PRES.
Low pressure inside the
heat pump
OVER HEAT
Domestic hot water over-
heating
(Water temperature
> 87 °C)
ANTI -BACT.
Anti-legionella function in-
complete. Water-heating
could not be finished.
80
Possible cause
No water in the do-
mestic hot water cyl-
inder
Water temperature too
high (> 75 °C)
Water temperature
sensor removed from
the domestic hot water
cylinder
Water temperature
sensor defective
Air flow too low
Air inlet/outlet opening
blocked
Air pipe blocked
Pipeline too long or too
many elbows
Evaporator contamin-
ated
Air temperature sensor
missing from the air
flow
Air flow too low
Air inlet/outlet opening
blocked
Air pipe blocked
Fan blocked or defect-
ive
Evaporator contamin-
ated and blocked
Evaporator frozen
Air temperature sensor
missing from the air
flow
Water temperature
sensor defective
Water temperature
sensor removed from
the domestic hot water
cylinder
Water flow too high
Set target cylinder tem-
perature too high
Malfunction of the elec-
tric back-up heater
Use of the electric
back-up heater not au-
thorised
Solution
Checking that the
product is correctly
filled with water and
purged
Replacing the water
temperature sensor
Checking that the water
temperature sensor is
sitting correctly in the
cylinder dry pocket
Checking that the air
flows through the en-
tire pipework system
without any problems
Check the pipe length
Checking the status of
any filters present in
the air pipes
Checking that the
evaporator is free of
dust
Positioning the air tem-
perature sensor cor-
rectly
Checking that the fan is
running
Checking that the air
flows through the en-
tire pipework system
without any problems
Check the pipe length
Checking the status of
any filters present in
the air pipes
Checking that the
evaporator is free of
dust
Positioning the air tem-
perature sensor cor-
rectly
Checking that the sensor is
correctly positioned in the
pocket
Manually start the new
cycle for heating the
water
Reducing the target
cylinder temperature
Checking, cleaning or
replacing the electric
back-up heater
In the settings, au-
thorise the use of the
electric back-up heater
(e.g. for high-tariff peri-
ods)
Installation and maintenance instructions 8000015884_00
Temporary operation
Heat pump decommis-
sioned.
The reset must be imple-
mented manually.
Possible operation of the
back-up heater.
Heat pump decommis-
sioned.
The selected back-up
heater keeps the water
temperature at 38 °C.
Heat pump decommis-
sioned.
The selected back-up
heater keeps the water
temperature at 38 °C.
Heat pump decommis-
sioned.
Resetting is effected auto-
matically.
The product remains in
operation.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

0010026817

Inhaltsverzeichnis