Live Surveillance

The display of the camera images for live surveil-
lance is independent of the recording activity of the
recorder.
To display a camera image as a full image, dou-
ble-click it with the mouse pointer (left mouse but-
ton). If a camera can be remote-controlled, it can be
operated in full image display (
return to the split screen, double-click once again.
Alternatively, switchover will also be possible via
the buttons on the recorder on or the infrared remote
control.
DMR-180 and DMR-184: Select the camera
channel CH 1, CH 2, CH 3 or CH 4 for full image dis-
play with the buttons
,
,
,
numerical keys (27) of the remote control. To return
to the split screen, press the button
ton ALL (28).
DMR-188: Select the desired channel CH 1 to
CH 8 for full image display with the buttons
(5) or directly select it with the numerical keys
(27) on the remote control. To return to the split
screen, press the button
(6) or the button ALL
(28). Each time the button is pressed again, the
image will switch between quad display of channels
CH 1 to CH 4, CH 5 to CH 8 and simultaneous dis-
play of all eight channels.
7.1

Display options

To define the camera image for live surveillance and
to define if date and time are to be inserted and to
configure the sequence function:
1) Activate the
MAIN MENU
(fig. 10).
CAMERA
2) Activate the submenu
(fig. 14).
3) In the column
LIVE
, define for each camera chan-
nel in the list field if it is to be displayed for live
surveillance (
ON
) or not (
OFF
). The setting will also
determine if there will be an audio signal for the
corresponding channel.
4) For DMR-188 only:
For setting the camera channels 5 – 8, click
Then click
PREV.
to return to the previous menu
page.
5) In the list field next to
DISPLAY TIME WHILE IN
LIVE VIEW
, define if the date and the time are to
be inserted for live surveillance (
6) To configure the sequential switching, click
AUTOSEQ
(
chapter 7.2).
7) To reset all settings of this submenu to the factory
DEFAULT
settings, click the button
8) To store the settings, click the button
confirm the message inserted "
fully!
" by clicking the button
9) To exit the submenu, click the button
right mouse button or press the button MENU /
ESC (7) or MENU (32).
7.2

Configuring the sequence function

With the sequence function, the display will change
automatically during live surveillance. To configure
the sequence function, activate the submenu
AUTOSEQ
(fig. 20) via the button
menu
CAMERA
chapter 11). To
(5) or with the
Submenu AUTOSEQ
(6) or the but-
1) In the list field next to the camera channels, select
the dwell time (in seconds) for full image display
of each camera or select
and
to be displayed as a full image for the sequence
function. For
be shown and define its dwell time.
DMR-188: Apart from the times for full image
displays of channels 1 to 8, it will also be possible
to define the times for the quad displays of chan-
nels 1 to 4 and 5 to 8 and for the display of all
eight channels.
2) To reset all settings of this submenu to the factory
settings, click the button
3) To store the settings, click the button
confirm the message inserted "
fully!
" by clicking the button
4) To exit the submenu, click the button
DISPLAY SETUP
/
right mouse button or press the button MENU /
ESC (7) or MENU (32).
7.3
Activating / deactivating the sequence
function
To start the sequence function, press the button
PAUSE
control
(31) after exiting the OSD menu.
NEXT
.
will be inserted and the dwell time for each view will
be counted down to 0 before proceeding to the next
view. Camera channels without video signal will be
skipped automatically.
To end the sequence function, press the button
once again.
ON
) or not (
OFF
).
.
APPLY
, then
Saved success-
OK
.
EXIT
or the
AUTOSEQ
in the sub-
/
DISPLAY SETUP
(fig. 14).
OFF
if the camera is not
QUAD
, define if the quad display is to
DEFAULT
.
APPLY
Saved success-
OK
.
EXIT
(11) on the recorder or on the remote
AUTOSEQ
8

Recording

The video signals will be recorded on the internal
hard disk. This hard disk must be formatted prior to
the first recording by the video recorder. To save
storage space, the video signals will be compressed
according to the highly efficient standard H.264
(MPEG-4 / AVC). The image quality of the recording
(and thus the compression rate) will be adjustable.
8.1

General settings for recording

Prior to the first recording, define the camera chan-
nels intended for recording, the resolution and the
quality is to be used, define if an audio signal is to
be recorded as well and the maximum size of the
video files.
MAIN MENU
1) Activate the
2) Activate the submenu
(fig. 21).
, then
Submenu RECORD SETUP
or the
3) In the line
CHANNEL
, define for each camera chan-
nel in the list field if it is to be available for record-
ing (
ON
) or not (
OFF
).
RESOLUTION
4) In the line
els horizontal × vertical) for recording the video
signal. The resolution will also depend on the
video standard used (
DMR-188: It will not be possible to select the
resolution; recordings will always be made with
the resolution CIF.
D1
704 × 576
HD1
704 × 288
CIF
352 × 288
QUALITY
5) In the line
, select the quality for record-
ing the video signal. With increased quality
(
NORMAL
GOOD
required will also be increased.
6) In line
AUDIO
, define if the audio signals are to be
recorded as well (
ENABLE
DMR-188: This recorder only has one audio
input. In the list field next to
possible to select the camera channel for record-
ing the audio signal. If
signal will be recorded.
PACK TIME
7) In the list field
size of the video files, i. e. the recording time after
which a new file will be created automatically.
8) To reset all settings of this submenu to the factory
settings, click the button
9) To store the settings, click the button
confirm the message inserted "
fully!
" by clicking the button
10)To exit the submenu, click the button
right mouse button or press the button MENU /
ESC (7) or MENU (32).
Furthermore, it can be defined if the date and the
time inserted in the image are also to be recorded:
CAMERA
1) Call the submenu
via the main menu (fig. 10).
2) In the list field next to
RE CORD ING
, define if the date and the time in the
image are also to be recorded (
3) To store the settings, click the button
confirm the message inserted "
fully!
" by clicking the button
GB
(fig. 10).
RECORD
/
RECORD SETUP
, select the resolution (pix-
chapter 6.2.2).
PAL
NTSC
704 × 480
704 × 240
352 × 240
BEST
), the storage space
) or not (
DISABLE
).
AUDIO REC
, it will be
OFF
is selected, no audio
, select the maximum
DEFAULT
.
APPLY
, then
Saved success-
OK
.
EXIT
or the
DISPLAY SETUP
/
(fig. 14)
DISPLAY TIME WHILE
ON
) or not (
OFF
).
APPLY
, then
Saved success-
OK
.
27

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dmr-188Dmr-184

Inhaltsverzeichnis