1 2 Code Name/Function
Read min measuring range
x x 176
Read max measuring range
x x 177
Read measuring range unit
x x 178
Read measuring range decimal point
x x 179
Read kind of measuring of sensor
x x 180
Read kind of measuring of display
x x 199
The measuring- and display range values read back from the interface are always in the
selected measurement unit!
When using the interface, the auto-range-function should be turned off. If auto-range is
activated, the returned value ar based on the resolution of the smallest ranges, there
may be returned extreme values like 123400.0 µS/cm instead 123.4 mS/cm.

14 Error and System Messages

Error messages for measurement
Description
Battery empty
No display or
confused
Mains operation: wrong voltage or polarity
characters,
System error
Device does not
react on key press
Device defective
Measured value above allowable range
Err.1
Sensor defective
Measured value below allowable range
Err.2
Sensor defective
System error
Err.7
Value extremely out of measuring range
Could not calculate display value
• measuring range or input range
----
• measured values are instable
> CAL <
Either preset calibration interval has
CAL flashing in
expired or last calibration is not valid
upper display
Error messages for automatic cell correction adjustment/calibration:
CAL Err.1
Cell correction too high
Cell correction too small
CAL Err.2
CAL Err.3
Solution of wrong range
Wrong temperature
CAL Err.4
If "bAt" is flashing the battery will be exhausted soon. Further measurements are possible for short time. If
"bAt" is displayed continuously the battery is ultimately exhausted and has to be replaced. Further
measurements aren't possible any more.
Operating Manual CO 301
exceeded
_____________________________________________________
1 2 Code Name/Function
Read power off time (Conf-P.oFF)
x
222
Set power off time (Conf-P.oFF)
x
223
Read real time clock (CLOC)
x
233
Set real time clock (CLOC)
x
234
Reset
x
240
Program version
x
254
What to do?
Replace battery
Check power supply, replace it if necessary
Disconnect battery and power supply, wait shortly,
then reconnect
Return to manufacturer for repair
Check: pressure not within sensor range?
-> measuring value to high!
Return to manufacturer for repair
Check: pressure not within sensor range?
-> measuring value to low!
Return to manufacturer for repair
Return to manufacturer for repair
Value extremely out of measuring range
Check range parameter
Wait for signal regulation of the device
Device has to be calibrated!
Determined cell correction must not exceed 1.2
Determined cell correction must not fall below
0.8
Wrong solution / far beyond tolerance
Beyond permitted temperature:
0.0 – 34.0 °C
Seite 13 von 16
_____________________________________________________________________________
(or 0.0 – 27.0 °C at 111.8 mS/cm)