Problem
A
or
symbol is
shown instead of numbers
on the Temperature Dis‐
play.
The lamp does not work.
The compressor operates
continually.
There is too much frost
and ice.
Possible cause
The mains plug is not
connected to the mains
socket correctly.
There is no voltage in the
mains socket.
The door is left open.
Temperature sensor
problem.
The lamp is in stand-by.
The lamp is defective.
Temperature is set incor‐
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The door is not closed
correctly.
The "FastFreeze func‐
tion" or "FastCool func‐
tion" is switched on.
The door is not closed
correctly or the gasket is
deformed/dirty.
The water drainage plug
is not correctly posi‐
tioned.
Appliance is fully loaded
and it is set to the lowest
temperature
ENGLISH
Solution
Connect the mains plug to
the mains socket correctly.
Connect a different electrical
appliance to the mains sock‐
et. Contact a qualified elec‐
trician.
Close the door. Refer to
"Door open alarm"
Contact the nearest Author‐
ised Service Centre (the
cooling system will continue
to keep food products cold,
but temperature adjustment
will not be possible).
Close and open the door.
Contact the nearest Author‐
ised Service Centre.
Refer to "Operation".
Wait few hours and then
check the temperature
again.
Refer to climate class chart
on the rating plate.
Allow food products to cool
to room temperature before
storing.
Refer to "Closing the door".
Refer to "FastFreeze func‐
tion" or "FastCool function".
Refer to "Closing the door".
Position the water drainage
plug in the correct way.
Set a higher temperature.
Refer to "Operation".