Installation and Assembly
4.3
Installing the Encoder
WDS-Pxxx Series
Fix the coupling half to the encoder shaft.
Mount the flange on the encoder.
Mount the encoder/flange assembly on the draw-wire mechanism.
WDS-Z60 Series
Mount the flange on the encoder. Connect the shaft of the encoder to the shaft of the draw-wire mechanism.
Mount the encoder/flange assembly on the draw-wire mechanism.
Press the supplied sealing cap into the opening in the flange housing.
i
Make sure that the measuring wire is always tensioned by the spring motor in order to prevent it from jumping off the cable
drum.
Flange
Fig. 8 Mounting of flange and encoder, WPS-MK60
i
Make sure that the encoder shaft is not rotated during installation.
Observe the installation instructions provided by the encoder manufacturer.
wireSENSOR, Z60-M / P96-M / P115-M / P200-M
Encoder
Synchro flange
Fig. 9 Mounting of flange and encoder, WDS-Pxxx
3xM4 screws DIN7985
with serrated lock washers
4xM4 cylinder screws DIN912,
with serrated lock washers
Coupler Rotex GS
with grub screw M3
Elastomer
Encoder
coupler