Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notes - HANSGROHE Raindance Select 2jet Showerpipe 27126000 Gebrauchsanleitung, Montageanleitung

Vorschau ausblenden Andere Handbücher für Raindance Select 2jet Showerpipe 27126000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Safety Notes

� Gloves should be worn during installation to prevent crushing and cutting
injuries.
� The product may only be used for bathing, hygienic and body cleaning
purposes.
� The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
� Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
� Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
� The product may not be used as a holding handle. A separate handle must b e
installed.
� The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of
installation height will also change the minimum height, and that the altered
mounting dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no
weak points.
• The filter insert must be used to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• The product is not designed to be used with steam baths!
• If the water connections are not stabil mounted, the fitting must be fixed with
2 to 4 extra screws (see page 32, fig. A1 - A11). With this type of installation,
take care not to puncture the water pipe! If the water connections are stabil
mounted, no extra screws are required (see page 33, fig. B1 - B11).
Technical Data
Operating pressure:
27126000 / 27126400Recommended operating pressure:
27127000 / 27127400Recommended operating pressure:
Test pressure:
Hot water temperature:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Fault
Insufficient water
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
Temperature regulation not possible
Safety stop button not operating
4
English
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
• The check valves must be checked regularly according to EN 806-5 in
• To guarantee the smooth running of the thermostat, it is necessary from time to
Special accessories (order as an extra)
To empty the overhead shower after use, hold it in a slightly inclined position.
max. 1 MPa
0,15 - 0,5 MPa
0,2 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
150±12 mm
cold right - hot left
70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- filter insert shower dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Spring defective
- Button calcified
Assembly (see page 32)
Do not use silicone containing acetic acid!
Safety Function (see page 36)
Adjustment (see page 36)
Maintenance (see page 40)
accordance with national or regional regulations (at least once a year).
time to turn the thermostat from total hot to total cold.
Dimensions (see page 38)
Flow diagram (see page 38)
Dismounting handle #98369000 (see page 41)
Spare parts (see page 44)
tile-matching-disk Chrome Plated #92143000 (see page 44)
Cleaning (see page 42)
Operation (see page 37)
Test certificate (see page 41)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Clean filter insert between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 60 ºC
- Exchange thermo cartridge
- Clean spring and/or button, exchange if necessary

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis