4.3.3
Ethernet
In order to use various web tools, the pump should be connected to network
or a personal computer over Ethernet plug. Use CAT-4 or better network
cable connected to "PATCH" configuration if plugged into a network or wired
as "CROSSOVER" for connection to PC.
g G o B b O br BR
»Crossover cable wire configuration
When the pump is connected to network or another computer, it can be
reached by typing its IP address or NetBIOS name into browsers address
line. Default IP address is 192.168.0.245 and default NetBIOS name is
»nmtpump«.
•
If more than one pump will be connected into network, each
individual pump should have its IP address and NetBIOS
name changed and noted. That will prevent network
collisions and provide naming service in relation to pump
function.
•
To achieve pump IP protection, network cable should
be lead over the inlet and then crimped to a connector.
Ethernet plug is galvanicaly insulated, but the rest of the
cabling could still present shock hazard. All connections
should be made with the power turned off.
4.3.3.1 Twin pump connection
Both pumps are interconnected with a cross-over network cable. If you wish
to connect the pumps to a local network, replace the network cable with
two connections to the nearest network switch. The left pump has the same
network settings as an individual pump. NetBIOS name is »nmtpump« and IP
address is 192.168.0.245. Right pump netBIOS name is set to »nmtpump2«
and IP address is 192.168.0.246. On the »Network« page, »Twin mode with
IP:« field assigns Twin IP address. Left pump has the IP address of the
right pump in this field, while the right pump has the address of the left one.
o O g B b G br BR
o O g B b G br BR
Patch cable wire configuration
27
o O g B b G br BR