5.

Operation of the Unit

An operator is necessary as accessories for local or external (Option: cable 00.F5.0C0-1xxx)
programming of the frequency inverter KEB COMBIVERT. In order to avoid malfunctions
the frequency inverter must be brought into status nOP before plug-on/remove of the
operator (open control release). During starting of the frequency inverter it always starts
with the last stored values/factory setting.
5.1

Operator

Digital operator with operation and display: Part No. 00.F5.060-1000
Interface operator additionally with serial interface: Part No. 00.F5.060-2000
5
4
3
2
1
9
8
7
6
RS232-cable 3m
PC / Operator
Part No. 00.58.025-001D
Interface check
BUS-operation "LED on"
(only 00.F5.060-2000)
Use only the operator interface for the serial data transfer according to RS232/
485. The direct connection of a PC to a frequency inverter is only permissible
with a special cable (HSP5 Part No. 00.F5.0C0-0001), otherwise it would lead to
the destruction of the PC interface!
PIN
RS485
Signal
1
2
TxD
3
RxD
4
A'
RxD-A
5
B'
RxD-B
6
VP
7
C/C'
DGND
8
A
TxD-A
9
B
TxD-B
Housing (PE)
Operation of the Unit
START
ENTER
FUNC.
F/R
SPEED
STOP
ANTRIEBSTECHNIK
ANTRIEBSTECHNIK
Meaning
reserved
transmission signal/RS232
receive signal/RS232
receive signal A/RS485
receive signal B/RS485
Voltage supply-Plus +5V (I
data reference potential
receive signal A/RS485
receive signal B/RS485
SUB-D 9 pole female SUB-D 9-pole male
2
3
5
PC
5-digit LED display
Status-/Error display
Normal "LED on"
Error "LED blinks"
Double function

keyboard

RS232/RS485
(only 00.F5.060-2000)
= 10 mA)
max
2
3
7
F5-Operator