Herunterladen Inhalt Inhalt Diese Seite drucken

Preparing The Tube; Wiring - SOMFY ILMO2 50 io Anleitung

Vorschau ausblenden Andere Handbücher für ILMO2 50 io:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
ILMO2 50 io

2.1.2. Preparing the tube

1) Cut the roller tube to the required length, depending on the
motorised product.
2) Deburr the roller tube and remove the swarf.
3) For the roller tubes which are smooth inside, cut a notch with the
following measurements:
2.1.3. Motorisation-tube assembly
1) Slide the motorisation into the roller tube.
For roller tubes which are smooth inside, position the notch
previously cut on the boss on the crown.
2) The drive wheel must be locked in place to prevent any movement
in the roller tube:
• This can be done either by attaching the roller tube to the drive
wheel using 4 x Ø 5 mm self-tapping screws, or by using 4 x
Ø 4.8 mm steel pop rivets positioned 5 mm to 15 mm from
the outer rim of the drive wheel, regardless of the roller tube.
Attention
The screws or pop rivets must only be fastened onto the drive
wheel and not on the motorisation.
• Alternatively, a drive wheel stop can be used for tubes which are not smooth.
2.1.4. Mounting the tube-motorisation assembly
1) Install and fix the motorisation-tube assembly onto the end
f
bracket
and onto the motorisation bracket
Attention
Ensure that the motorisation-tube assembly is secured onto
the end bracket. This operation prevents the motorisation-tube
assembly from coming out of the end bracket mounting.
2) Depending on the type of bracket, fit the stop ring

2.2. WIRING

• Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
• Attach cables to prevent any contact with moving parts.
• If the motorisation is used outdoors, and if the power supply cable is a type H05-VVF cable, the cable
should be installed in a UV-resistant duct, e.g. under a gland.
• The ILMO2 50 io cable can be removed. If it becomes damaged, replace it with an identical cable.
• Leave the motorisation power supply cable accessible: it must be easy to replace.
• Always make a loop in the power supply cable to prevent water entering the motorisation!
Copyright
2018-2020 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
d
 = 4 mm,
e
 = 28 mm.
g
:
1)
3)
1)
2)
1)
g
2)
h
h
.
EN
2)
e
d
15 mm
5 mm
L
f
23

Werbung

Inhaltsverzeichnis
loading