CAUTION:
Do not put the low-voltage
cable in a coil or below the charging station
plate. The coil causes interference with the
signal from the charging station.
•
Put the power supply in an area with a roof and
protection from the sun and rain.
•
Put the power supply in an area with good airflow.
•
Use a residual-current device (RCD) with a tripping
current of maximum 30 mA when you connect the
power supply to the power outlet.
Low-voltage cables of different lengths are available as
accessories.
39.8 To examine where to install the
virtual boundaries
CAUTION:
If the work area is adjacent
to water bodies, slopes, precipices or a
public road, there must be a protective wall.
The wall must be minimum 15 cm / 6 in. in
height.
CAUTION:
Do not let the product
operate on gravel.
•
For careful operation without noise, isolate all
obstacles such as trees, roots and stones.
•
Make a blueprint of the work area before you install
the virtual boundaries.
39.9 To install map objects near
buildings and trees
When the product operates it must have unimpeded sky
view to use the satellite signals for navigation.
•
Make sure that 90° section of the sky is
unimpeded.
1944 - 001 - 13.01.2023
90°
Note:
Objects that are less than 1 m / 3.3 ft. in
height does not interfere with the operation of the
product.
Note:
Tree canopies that are less than 4 m / 13
ft. in diameter does not interfere with the operation
of the product. If there are many small trees
put together in an area, if the diameter of their
canopies put together is less than 4 m / 13 ft. they
do not interfere with the operation of the product.
•
For trees with tree canopies that is more than 4
m / 13 ft. in diameter (A), make a stay-out zone (B)
around the trees.
•
For L-shaped objects higher than 1 m / 3.3 ft,
install the virtual boundary at a minimum distance
(C) of 1.5 m / 5 ft. from it.
A
B
Installation - 109