A. Operating instructions
Please reer to the technical drawings
on page 2 or more inormation.
Functions
The AD-series are combined units
that will both clean and dehumidi-
y the indoor air. The air puriying
unction is always active as long
as the unit is running. Activate the
dehumidication to remove excess
moisture. When dehumidication is
active the compressor starts and the
icon is lit. When the set humidity level
is reached, the icon is fashing.
Modes
The unit has 4 dierent modes;
manual, automatic, quiet, or clothes
dry mode (clothes dry mode is only
available when dehumidiying).
Manual mode
Set an speed manually. Choose
between 4 an speeds in dehumidi-
cation mode and 5 an speeds in air
purication mode. I dehumidication
is activated, set desired humidity
level manually.
Quiet mode
The unit works on the lowest an
speed. The air quality indicator is
shut o.
Clothes dry mode
(dehumidication only).
Use this unction or the quickest
drying o clothes and laundry. The
unit will work on maximum an speed
continuously; humidity level and an
speed cannot be set.
Automatic mode
In air purication mode, the an
speed is set automatically depending
on the air quality o the room. The air
quality is indicated by the light on the
ront o the unit;
• Green: no pollution detected.
Fan works on speed 1.
• Blue: light pollution detected.
Fan works on speed 2.
• Yellow: moderate pollution
detected. Fan works on speed 3.
• Purple: heavy pollution detected.
Fan works on speed 4.
• Red: very heavy pollution detected.
Fan works on speed 5.
English
I dehumidication is activated the
unit automatically sets an speed ac-
cording to ambient relative humidity:
• 60% RH or below: dehumidication
stops, the an runs on speed 1
• 60-65% RH: an runs on speed 2
• 66-70% RH: an runs on speed 3
• 71% RH or above: an runs on
speed 4
Set desired humidity level
When the set humidity level is
reached the unit stops automatically.
The set humidity level is shown or
a ew seconds in the display. CO
means the unit will run continuously,
regardless o ambient humidity.
Set timer for shut off
Set time or automatic shut-o
between 1 and 12 hours. Press the
timer button repeatedly until the timer
display is blank to deactivate. Ater
the set time has passed the unit is
shut o. To restart it, you need to
manually press the Power button.
Select an speed
There are 4 an speeds or dehumidi-
cation and 5 an speeds or air pu-
rication. A higher an speed means
quicker air cleaning and dehumidi-
cation. During dehumidication, when
the set humidity level is reached,
both the compressor and the an
motor stop or 60 minutes.
Ater 60 minutes, the an will start
and run or 3 minutes to sense the
surrounding moisture level. I the
humidity level has not increased, the
machine will continue to stand still or
60 minutes and then start the an or
3 minutes.
I it is higher than the set limit, both
the compressor and motor will start
again.
Child lock
Press and hold the child lock button
or 3 seconds to activate or deacti-
vate the child lock. When activated,
all buttons are locked.
Show room temperature
Press and hold the mode button to
display room temperature. When
released, the display will return to
showing ambient humidity level.
13
B. Security functions
Automatic shut o unction
As a security unction, the unit au-
tomatically shuts o i no button has
been touched or 12 hours. Press
any button to reset the 12-hour
countdown.
To deactivate this unction, press and
hold the timer button and child lock
button simultaneously or 5 seconds.
The water ull indicator fashes and
a buzzer is heard when the unction
is deactivated. Repeat this action to
reactivate the unction.
Compressor protection
(dehumidication only)
When shut o, the compressor has a
5-minute delay unction beore star-
ting again to protect the compressor.
Shut off at low or high temperature
(dehumidication only)
When the temperature is below 3°C
or above 40°C the unit will automati-
cally stop dehumidiying and only the
an will run. The unit will restart dehu-
midication when the temperature is
within the range o 5°C to 38°C.
Low humidity unction
(dehumidication only)
When the ambient humidity level is
30% or lower, the display shows LO
and the compressor shuts o. It will
resume when the ambient humidity
is 32% or above. When the ambient
humidity is above 91% the display
shows HI (the unit will run as normal).
Water overfow protection
(dehumidication only)
When the water bucket is ull, the unit
stops, the water ull icon fashes, and
a buzzer is heard. Empty the water
bucket to restart the unit (see the
section about the water bucket)
Overheat protection
(dehumidication only)
When the unit is dehumidiying at
high room temperature and ambient
humidity level, the an speed may
automatically be increased to pre-
vent the unit rom over-heating. The
an speed will be restored to the set
value when the ambient humidity
level decreases.