Photoelectric Sensors
Red light diffuse reflective energetic BOS 18E-PI-RD30-S4 with IO-Link
With Teach Channel: Dynamic Teach. Dynamic Teach-In of both setpoints
Principle
Dynamic teach-in allows you to set the switching point
without interrupting the process.
Typical application:
Sensitivity setup to a moving object to be detected within a
certain distance range. (Window Mode).
During the teach procedure, which begins with the Start
command and ends with the Stop command, the sensor
carries out measurements and determines the minimum
and maximum of the obtained values. The Teach Apply
command determines the switching points SP1 and SP2.
Teach-In Status
Teach Flags
SP2
SP1
TP2
TP1
TP2
TP1
Example for:
"0" = TP1 of SP2 not set
or not successfully set
"1" = TP1 of SP2 success-
fully set
Instructions
Precondition:
Sensor is installed, aligned to the moving target, and
operated in IO-Link mode.
Procedure:
1. Start Dynamic Teach:
Send System command 0x47 to sensor.
Access Index
Value
W
0x0002
0x47
www.balluff.com
System commands
Teach State
0 = IDLE
1 = SP1 SUCCESS
2 = SP2 SUCCESS
3 = SP12 SUCCESS
4 = WAIT FOR COMMAND
5 = BUSY
6 = reserved
7 = ERROR
Remark
SP1 Dynamic Teach Start
2. Wait for a minimum of one process cycle is completed.
( > 10min: Dynamic Teach is aborted automatically.
Sensor keeps operating with last valid Setpoint set-
tings).
3. Stop Dynamic Teach:
Send System command 0x4A to sensor.
Access Index
Value
W
0x0002
0x4A
4. Verify successful sensitivity setup:
Read and verify parameter Teach-In Status with Index
0x003B.
Access Index Value
R
0x003B
0xF4
Dynamic sensitivity setup of SP1
and SP2 successful.
Teach-In State = WAIT FOR
0x07
Teach-In State = ERROR
5. Store and accept Setpoints SP1 and SP2:
Send System command 0x40 to sensor.
Access Index
Value
W
0x0002
0x40
6. Verify correct acceptance of SP1 and SP2:
Read and verify parameter Teach-In Status with Index
0x003B.#
Access Index
Value
R
0x003B
0x03
SP1 and SP2 accepted success-
Teach-In State = SP12 SUCCES
0x07
Teach-In State = ERROR
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Tel. + 49 7158 173-0
Fax +49 7158 5010
balluff@balluff.de
Remark
SP2 Dynamic Teach Stop
Meaning
Result
Proceed with 5
COMMAND
Back to 1
Remark
Teach Apply
Meaning
Result
Teach-In
fully.
successful
Back to 1
english