Block customer's drive shaft to prevent rotation.
Mount the coupling (1) on the encoder
Ensure that it does not touch the encoder flange.
Mount servo-clamps (2) with M3 screws (4).
Do not fully tighten screws, turn the servo-clamps (2) such that the encoder flange
can be slid into the centering fixture (3).
Slide the encoder together with the mounted coupling (1) onto the drive shaft and
centering fixture (3).
Engage the servo-clamps (2) by rotating into the groove and tighten slightly. Mount
the coupling (1) on the drive shaft. The coupling must not be subjected to mechan‐
ical stress.
Tighten up all 3 screws (4) on the servo-clamps (2).
Establish an electrical connection with the power switched off.
Switch on the voltage and check that the encoder is functioning.
2
1
3
Figure 12: Mounting servo flange with servo-clamps
Block the customer's drive shaft.
Install the coupling (1) on the encoder.
Ensure that the coupling (1) does not touch the encoder flange.
Slide the encoder together with the mounted coupling (1) onto the drive shaft and
mounting spigot in the clamping direction (2).
Install the encoder with 4 M5 screws (3) and washers (4).
Install the coupling (1) on the drive shaft. The coupling must not be subjected to
any mechanical stress.
Establish electrical connections with the voltage switched off. Switch on the power
and check the function of the encoder.