Current limiter
Connection type
settings
1x16A
1 phase, 1 neutral conductor
1x13A
1 phase, 1 neutral conductor
1x10A
1 phase, 1 neutral conductor
1x06A
1 phase, 1 neutral conductor
Voltage between line and neutral conductor must be 220–240 V~.
For appliance types: BI1CA..., BI6CA..., BI6CB..., BI7CA..., BI8CA..., BI8CB..., BI9CE...
NOTE!
Note: The appliance type can be found on the rating plate on the bottom of the appliance.
Voltage between line and neutral conductor must be 220–240 V~. Voltage between lines must be
380–415 V~. Power cord core cross sectional area should be at least as listed in Table for the
following current limiter settings which should be adjusted to your circuit breakers:
Current limiter
Connection type
settings
2x16A
2 phases, 1 neutral conductor
2x13A
2 phases, 1 neutral conductor
2x10A
2 phases, 1 neutral conductor
2x06A
2 phases, 1 neutral conductor
2x16A
2 phases, 2 neutral conductors
(only for NL)
1x32A
1 phase, 1 neutral conductor
1x25A
1 phase, 1 neutral conductor
1x20A
1 phase, 1 neutral conductor
1x16A
1 phase, 1 neutral conductor
1x13A
1 phase, 1 neutral conductor
1x10A
1 phase, 1 neutral conductor
1x06A
1 phase, 1 neutral conductor
1 phase, 1 neutral conductor (220–240 V~, 50-60 Hz)
L = black/brown
N = blue
= yellow-green
Electrical installation
Power cord
Number and cross section
type
of Power cord wires
H05V2V2-F
3x1,5 mm²
H05V2V2-F
3x1,5 mm²
H05V2V2-F
3x1,5 mm²
H05V2V2-F
3x1,5 mm²
Power cord
Number and cross section
type
of Power cord wires
H05VV-F
4x1,5 mm²
H05VV-F
4x1,5 mm²
H05VV-F
4x1,5 mm²
H05VV-F
4x1,5 mm²
H05VV-F
5x1,5 mm²
H05VV-F
3x4,0 mm²
H05VV-F
3x4,0 mm²
H05VV-F
3x4,0 mm²
H05VV-F
3x4,0 mm²
H05VV-F
3x4,0 mm²
H05VV-F
3x4,0 mm²
H05VV-F
3x4,0 mm²