Application
4
Application
The pressure transducer is suitable for measuring static and dynamic liquid
pressure. For measuring gas pressure, mechanical protection must be
installed. This is available for different measuring ranges, graded from 10 to
200 bar and with various mechanical connection options (see section 12
"Options", page 23).
All media that will not corrode the steel stated in the specifications are suitable
as measurement media. The pressure transducer is secured for the pressure
connection by its threaded connection piece and can be mounted in any
position. For each individual case, please note the instructions in section 6
"Mounting", page 11.
P60
9
A05363_01_Y00_00 HBM: public