Herunterladen Inhalt Inhalt Diese Seite drucken

Transport; Storage; Care And Service; Troubleshooting Guide - Kärcher IVS 100/40 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für IVS 100/40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Transport

CAUTION
Risk of injury and damage
When transporting in vehicles, secure the device
against slipping and tipping over according to the appli-
cable guidelines.

Storage

CAUTION
Risk of injury and damage
Be aware of the weight of the device during storage.

Care and service

DANGER
Danger of injury
Danger of the device unintentionally starting and danger
of electric shock
Switch off the device and unplug the mains plug before
performing any work on the device.
Maintenance intervals / user maintenance
No periodic maintenance intervals are specified for this
device. The following maintenance is to be performed
as necessary:
● Wash the filter.
● Change the filter.
● Replace the filter.
Inspection and maintenance work
Have the vacuum cleaner regularly inspected according
to the respective national accident prevention regula-
tions. Maintenance work as specified by the manufac-
turer must be performed by a technically qualified
person at the specified regular intervals and in accord-
ance with the applicable regulations and safety require-
ments. Work on electrical components may only be
performed by a qualified electrician. Please contact a
KÄRCHER branch office if you have any questions.
Wash the filter
The filter can be washed out under running water.
ATTENTION
Risk of damage
Do not use washing agents or bleach. Only insert the fil-
ter into the device when it is completely dry.
Changing/replacing the filter
1
2
3
4
1
Filter chamber lid
2
Filter spreader
3
Main filter
4
Sealing ring
1. Release the lower end of the suction turbine hose
and pull it off.
2. Open the locks.
3. Remove the filter chamber lid.
4. Remove the filter.
5. Check the sealing ring for damage.
6. Insert the new filter in reverse sequence and take
care to ensure that the filter spreader is aligned cor-
rectly in the filter bag.

Troubleshooting guide

DANGER
Danger of injury
Danger of the device unintentionally starting and danger
of electric shock
Switch off the device and unplug the mains plug before
performing any work on the device.
The motor (suction turbine) does not start running
No electrical voltage present
 Check the socket and the power supply fuse.
 Check the mains cable and the mains plug of the de-
vice.
 Check all parts for clogging.
 Check the fit of all electrical connections.
No vacuuming operations, airflow escapes from the
suction hose.
Suction turbine rotating in the wrong direction
 Swap the pins on the plug.
English
11

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Ivs 100/55Ivs 100/75

Inhaltsverzeichnis