5.4.4.

Automatic Defrost

At low room temperatures, frost may build up at the evaporator during operation. The unit will
automatically start defrosting and the POWER LED blinking. The defrost control sequence is as
follows:
A. When the unit operates in the cooling operation, drying operation, the ambient temperature
sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop
operating for 10 minutes or the coil temperature up to 7°C, the unit restart to cool operating
mode.
5.4.5.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the
compressor restarting.
5.5 DRAINAGE
Manual drainage:
1) When the machine stops after the water is full, please unplug the power plug.
Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom
of the body.
2) Place the water container below the side water outlet behind the body.
3) Unplug the water plug, the water will automatically flow into the water container.
Notes:
1. Keep the water plug properly.
2. During drainage, the body can be tilted slightly backwards.
3. If the water container cannot hold all the water, before the water container is full, stuff the water
outlet with the water plug as soon as possible to prevent water from flowing to the floor or the
carpet.
4) When the water is discharged, stuff the water plug.
Press UP/DOWN repeatedly until the LED shows '00'.
Note: when press POWER will also exit the timer setting.