Herunterladen Inhalt Inhalt Diese Seite drucken

HBM Z16A Bedienungsanleitung Seite 21

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Type
Nominal (rated) load
Limit load
Breaking load
Relative permissible oscillatory
stress (oscillation width as per
DIN 50100)
Nominal (rated) displacement at
E
, approx.
max
Weight without cable, approx.
Degree of protection per DIN EN 60529
(IEC 529)
Cable length, six‐wire configuration
Material:
Measuring body + housing
Cable entry
Seal
Cable sheath
1)
As per OIML R60, with P
2)
Sensitivity and output resistance are matched in such a way on each transducer that the
measured value lies within the permissible error limits when they are connected in parallel.
3)
The values for non‐linearity (d
sensitivity (TC
) are recommended values. The sum of these values is within the cumulative error
S
limits according to OIML R60.
4)
Based on DIN 40050, Part 9 specifications, for road vehicles.
5)
As per EN 10088-1.
Z16A
E
max
E
L
E
d
F
srel
s
nom
G
= 0.7.
LC
), relative reversibility error (d
lin
A04000_03_Y00_00 HBM: public
Z16AD1
t
7.5
15
% of
E
max
0.20
0.27
mm
kg
IP68 (test conditions: 100 hours
under 1m water column);
IP69 K (water at high pressure,
steam cleaner)
Stainless steel
Stainless steel
Thermoplastic elastomer
) and temperature coefficient of
hy
Specifications
Z16AC3
20
15
150
> 350
70
0.27
0.20
0.27
2.3
4)
12 m
5)
5)
®
Viton
19