3.7
Ope ra ting hour meter
•
The operating hour me ter (1) can be used to call up va ri ous in -
for ma ti on
• Op er at ing hours in whole hours.
• En gine oil and air fil ter re place ment in ter vals are shown:
En gine oil & air fil ter re place ment in ter vals
1. Serv.-
Alarm
Dis play
CHG
OIL
In ter val
20 hours
Count down
—
Blink ing time 2 hours
1)
Spe ci al equip ment
1)
2. Serv.-
3. Serv.-
Alarm
Alarm
CHG
CHG
OIL
Air Fil ter
100 hours
50 hours
25 hours
25 hours
be fore
be fore
59
3. Ope ra ti on