Herunterladen Inhalt Inhalt Diese Seite drucken

HYDAC ELECTRONIC HPT 1000S Bedienungsanleitung Seite 38

Mit io-link-schnittstelle
Vorschau ausblenden Andere Handbücher für HPT 1000S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

14
 Q1 Configuration (Index 128):
Configuration of the switching output at PIN4 (C/Q1), % FS range for pressure
corresponds with the measured range, i.e. 0 .. 250 bar.
o Output function (OU) (Subindex 1):
Output function uses SP and RP at HNO and HNC (Hysteresis) or FL and FH
at FNO and FNC (window with fixed hysteresis 0.4 %FS, below FL and above
FH)
Default: Hysteresis function normally open (HNO) (selectable are Hysteresis
E
function normally open (HNO), Hysteresis function normally closed (HNC),
window function normally open (FNO
o Transistor function (P-n) (Subindex 2):
Transistor function at the output pin (NPN can not be used at the IO-Link
master ports)
Default: PNP (PNP, NPN or Push-Pull are selectable)
o Upper setting value (SP/FH) (Subindex 3):
Upper setting value in % FS with 2 decimal places, i.e. 3175 = 31.75 %.
Setting value corresponds with SP at HNO and HNC (Hysteresis) or FH at
FNO and FNC (F = Fenster = window).
o Lower setting value (RP/FH) (Subindex 4):
Lower setting value in % FS with 2 decimal places, i.e. 2550 = 25.50 %.
Setting value corresponds with RP at HNO and HNC (Hysteresis) or FL at
FNO and FNC (F = Fenster = window).
o Switching delay (Subindex 5):
Switching delay in ms for switching into the active condition.
o Switch-back delay (Subindex 6):
Switch-back delay in ms to switch in to the inactive condition.
 Q2 Configuration (Index 129): Configuration of the switching output at PIN2 (Q2).
The transistor function is constant (PNP). % FS range for pressure corresponds with
the measuring range, i.e. 0 .. 250 bar.
o Output function (OU) (Subindex 1):
Output function uses SP and RP at HNO and HNC (Hysteresis) or FL and FH
at FNO and FNC (window with fixed hysteresis of 0.4 % FS, below of FL and
above FH).
Default: Hysteresis function N/O (HNO) (selectable are hysteresis function N/O
(HNO), Hysteresis function N/C (HNC), window function N/O (FNO
function N/C (FNC))
o Upper setting value (SP/FH) (Subindex 3):
Upper setting value in % FS with 2 decimal places, i.e. 3175 = 31.75 %.
Setting value corresponds with SP at HNO and HNC (Hysteresis) or FH at
FNO and FNC (F = Fenster = window).
o Lower setting value (RP/FH) (Subindex 4):
Lower setting value in % FS with 2 decimal places, i.e. 2550 = 25.50 %.
Status: 2022-07-15
For operation in SIO mode only
Option for the device variant with an additional switching output at PIN 2
only.
HYDAC ELECTRONIC GMBH
)
, window function normally closed (FNC))
HPT 1000S IO-Link
)
, window
Part no.: 670021

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis