7. DIP Switch Settings

7.1 Operation Mode

The status module may be used as a regular display for the status or as a diagnostic device. The table
below illustrates the operation modes that are available. Set the desired operation mode using the DIP
switches 1 – 3 in their settings as shown below.
DIP Switch Position
(standard)

7.2 Allocation of Door Station Addresses

Every status module has a DIP switch. The door station address is set at this DIP switch. The door
stations address that is set here has to correspond to the door station address to which the status module
is connected. The table below shows the DIP switch setting in the door station with the corresponding DIP
switch setting at the status module.
If the DIP switch settings do not match, the status of a different door will be displayed.
Door station
DIP switch position of
address
corresponding door station
1
2
3
4
5
6
7
8
The status module can only recognize the allocation to a door station if the door station number
has been sent via the SKS Bus. This means, for example, that once the status module has been
connected and the same address is called again, the door station number will not be contained in
the command and the allocation is not (yet) completed. Consequently call any other calling
address.
Dokument Art. Nr. 97003300
Operation Mode
Status display at door station
Diagnostic device with a+/b- SKS Bus without data storage
Diagnostic device with a+/b- SKS Bus with data storage
~ 18 ~
DIP switch position
status module

Werbung

Inhaltsverzeichnis
loading