4. OPERATION
GENERAL INFORMATION
a. Capacity / Size: 2000g / 0,01 g
b. Display: LCD digital
c. Backlight: blue
d. Auto power save function: time off automatically programmagle (2.5 or 8 min.)
e. Units / Staging: g, ct, lb, oz, dr, GN, ozt, dwt, MM, tl.J, tl.T, tl.H, t (a total of 13 units)
f. Counting function: 1. per unit 2. the scale can calculate a percentage
g. Power: DC 9V adapter or AA batteries
h. Weight: 550g
5. FUNCTIONS OF THE KEYS
ON / OFF
Press the ON / OFF button to start the unit. Hold the button pressed for 3 seconds
to turn off the scale.
UNIT
EN
The unit change is possible by pressing the UNIT button. Then press up to reach the
desired unit.
PCS
Counting function: Press PCS to enter the counting function. The scales switches
from the weighing mode to the counting mode. By pressing this button, you can
switch from one mode to another.
ZERO
Press this button to subtract the weight of a container or any weight on the scale.
CALIBRATION AND PARAMETER SETTING
The calibration is performed in two stages. To calibrate the scale on 2kg, you need
standards of 1 and 2 kg. Turn on the scale. Hold pressed the zero key for 3 seconds
until the display shows „CALL".
The identification number of the scale appears (SCL)
Press briefly again ON / OFF to display „CAL-1". Wait until the scale displays „o"
Place the standard of 1 kg on the scale. It shows „PASS-1" and „CAL-2".
Then place the standard of 2 kg on the scale. It displays „PASS-2"
The scale is then calibrated.
12
FUNCTION OF TARE
1.
Place an empty container on the weighing platform until the balance indicates a
stable value. Then press „ZERO" Your balance now displays „0".
2.
To exit the tare function, remove the container and repress the „ZERO" button.
Your scale is back to normal.
AUTO-ZERO
1.
Press „ZERO" if the scale does not show „0" when nothing is placed on it.
2.
The area of auto zero is ± 2% of the total capacity of the scale.
DO NOT OVERLOAD THE BALANCE!
COUNTING MODE
1.
Press „PCS" to activate the counting function. Your weight unit is maintained.
2.
Press „UNIT", then choose between 100 and 1000 pieces and 10-1000 units by
repeated pressure.
3.
Place a unit / object on the scale. Press ON / OFF for the scale to remind the
weight of a unit.
PERCENTAGE MODE
1.
Press twice „PCS" then press „UNIT" to choose between 100.00 and 100.0
2.
After choosing the percentage of accuracy, place the weight on the scale and
press „ON / OFF." This weight now accounts for 100%. You can now place a
weight, the scale displays the percentage.
NOTE
To return to weighing mode, press „PCS"
ADVANCED SETUP:
ACTION / STEP
Value which can be
adjusted (bolded value is
factory setting)
Values can be changed by
UNITS button
0/1
1.
Scale must be turned off.
Simultaneously press and
hold ON/OFF and PCS
buttons for ~5 sec. –
display will show:
[0] F01.
DESCRIPTION
Units setting
0: without setting, move
to next step
1: open or close some of
the 13 units
13