OPERATION
CHARGING AND USE
The OPTIMAX Multi-Lite is available with different chargers. See Replacement
Parts for listing.
•
Fully charge your OPTIMAX Multi-Lite before first use.
•
A lamp head must be attached to the lamp in order to charge.
The OPTIMAX Multi-Lite lamp is equipped with a battery strength indicator
•
light. When the battery is of sufficient strength to power the lamp at its
specified performance, GREEN will be indicated. When the battery requires
recharging, RED will be indicated. The lamp will continue to function.
However, using it when the indicator is RED will shorten the life of the
battery.
•
Insert the smart charger (AC and DC supplied) into the tail-cap of the
OPTIMAX Multi-Lite and attach the plug to the corresponding live power
source. The flashlight can operate for approximately 90 minutes after a full
charge.
•
The included AC and DC smart chargers have indicator lights that will show
RED while charging and GREEN when the charge is complete. A full charge
will take approximately five hours.
•
Press the switch on to light and use the OPTIMAX Multi-Lite. Lamp indicator
will be GREEN.
CHANGING LAMP HEADS
The OPTIMAX Multi-Lite is available with three interchangeable,
LED lamp heads: UV-A, blue and white.
To remove or install a lamp head to the lamp base:
1.
Firmly hold the lamp base and lamp head.
2.
With the thumb and the forefinger, grip the
lamp head-locking ring and pull down (see
figure right).
3.
Remove or install the appropriate
wavelength lamp head in the socket by
pulling up or pushing down on the lamp head
and hold in place.
4.
Slide the lamp head-locking ring back into
place (covering the socket of the lamp head).
The grip will lock lamp head firmly into place.
When viewing UV fluorescence, use the flashlight in low-light conditions
to achieve the best inspection results. Wear the UV-absorbing spectacles
IMPORTANT
supplied for eye protection.
5