7.5.3

Index 0x005C: SSI Mono Time

The parameter defines the SSI mono time in µs.
Index
0x005C
Lower limit
Upper limit
Default
7.5.4

Index 0x005D: SSI Error Bit

The parameter SSI Error Bit defines an additional bit in the SSI protocol and is attached after the
"LSB-bit". Definition of the errors, see "Process Input Data - Error Status", page 60.
Index
0x005D
Value
Assignment
0x00
Disabled
0x01
Temperature Failure
0x02
Intensity Failure
0x03
Hardware Failure
0x04
Every Failure
0x05
Measurement Plausibility
7.5.5

Index 0x005E: SSI Output

The parameter SSI Output sets the physical measured parameter to be output on the SSI interface.
Index
0x005E
Value
Assignment
0x00
Position
0x01
Intensity
0x02
Speed
0x03
Position + Speed
0x04
Position + Toggle-Bit
Printed in the Federal Republic of Germany
06/15/2020
Subindex
Name
0
SSI Mono Time
20
250
20
Subindex
Name
0
SSI Error Bit
Description
Function switched off
Temperature range exceeded
Intensity value below
Hardware error
Combined error message
Position error
Subindex
Name
0
SSI Output
Description
Output of the Laser position
Output of the Laser intensity value
Output of the Laser actual speed
20 bit position data, 11 bit speed. The number
of data bits must be set to 31. Max. possible
resolution = 0.1 mm.
After the position data a toggle-bit is following.
This changes its condition (high->low or
low->high) after each SSI cycle and means,
that the position value was calculated new.
TR - ELE - BA - DGB - 0030 - 01
Length
Type
16 Bit
UIntegerT
Length
Type
8 Bit
UIntegerT
Length
Type
8 Bit
UIntegerT
 TR-Electronic GmbH 2020, All Rights Reserved
Access
rw
Access
rw
Default
X
Access
rw
Default
X