Malfunction remedy
Malfunction
Pump does not start.
Pump does not transport fluid
Insufficient delivered quantity /
unsatisfactory fountain display
Pump switches off after operating
briefly
Height of the fountain varies.
Technical data
Unit data
Description
Connection voltage
Mains frequency
Max. power consumption
Protection type
Max. immersion depth
Max. pump capacity
Max. pump head
Max. fountain height
Min. water depth
Filter supply surface area
Connection
Dimensions
Connection cable length
Weight
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Multifunctional nozzle clogged
Excessively soiled water
Water temperature too high
Impeller unit is blocked
Pump has run dry
Dynamic Function activated
Inlet port
Outlet port
Diameter
Height
Remedy
Check the mains voltage.
Check supply lines.
Clean
Clean
Clean the multifunctional nozzle.
Clean the pump. The pump auto-
matically switches on again once
the motor has cooled down.
Note maximum water temperature
of +35°C. The pump automatically
switches on again once the motor
has cooled down.
Disconnect the power supply and
remove obstacle. Then switch the
pump on again.
Flood the pump. Fully submerge
the pump for operation in the
pond.
Deactivate Dynamic Function
PondJet Eco
V AC
220 ... 240
Hz
50/60
W
190
IP68
m
4
l/h
10800
m
8.5
m
3.0
m
0.5
cm²
420
G1½
G1
mm
670
mm
540
m
20
kg
15.2
EN
33